Skip to content
Female VCR Diaphragm Sealed Valve — Product Photograph

HAL-LOK

Female VCR Diaphragm Sealed Valve

SKU FDGM-4-LC-PCTFE

Fluid & Gas Control

Model and Connection Size

Seat Material

Female VCR Diaphragm Sealed Valve. Select the documented size and construction for quotation.

Features:

  • Diaphragm metal-to-metal sealed to atmosphere

  • Optimal design for long cycle life

  • Handle with window provides visual indication of OPEN and CLOSE positions





Technical specification

Size 1/4" 3/8",1/2" 3/4"
Flow Coefficient 0.27 0.7 1.7
Maximum working pressure 250 psi (17.2 bar) 250 psi (17.2 bar) 250 psi (17.2 bar)
Working Temperatute PCTFE -40°C to 80°C(-40°F to 176°F) -40°C to 80°C(-40°F to 176°F)
Working Temperatute PFA,Vespel® -26°C to 177°C(-15°F to 350°F) -26°C to 177°C(-15°F to 350°F)
Leak Rate ≤1×10-9std cm3/s(He) ≤1×10-9std cm3/s(He) ≤1×10-9std cm3/s(He)

Models, sizes and drawing dimensions

Catalogue basic reference Specification
FDGM-4 VCRSize: 1/4in.; Dimensions,mm / A: 70.6; Dimensions,mm / B: 11.0; Dimensions,mm / C: 63.0; Dimensions,mm / D: 40.0; Dimensions,mm / E: 25.0; Dimensions,mm / F: 26.0; Dimensions,mm / G: 25.4; VCR size: 1/4 in.; Maximum working pressure: 250 psi (17.2 bar); Cv: 0.27; Seat options: PCTFE: -40 to 80°C; PFA or Vespel: -26 to 177°C; Internal/external helium leak rate: ≤1×10⁻⁹ std cm³/s
FDGM-8 VCRSize: 1/2in.; Dimensions,mm / A: 86.0; Dimensions,mm / B: 16.0; Dimensions,mm / C: 76.0; Dimensions,mm / D: 40.0; Dimensions,mm / E: 36.0; Dimensions,mm / F: 36.0; Dimensions,mm / G: 28.0; VCR size: 1/2 in.; Maximum working pressure: 250 psi (17.2 bar); Cv: 0.7; Seat options: PCTFE: -40 to 80°C; PFA or Vespel: -26 to 177°C; Internal/external helium leak rate: ≤1×10⁻⁹ std cm³/s

Available options

Option Values
Material 316L Stainless Steel
Seat material PCTFE | PFA | Vespel

Diaphragm Valve Seat Options

Seat: PCTFE (-40 to 80°C) | PFA (-26 to 177°C) | Vespel (-26 to 177°C). Maximum working pressure: 250 psi (17.2 bar). Confirm the selected construction and rating.

Ordering notes

  • Internal LABCON suffix identifies seat choice; catalogue basic model retained.

Catalogue drawing dimensions are nominal. Pressure and temperature ratings depend on the selected material, seals and configuration. Confirm the complete manufacturer ordering code with the quotation.

Source references and links are provided in the product documentation fields.

Technical Specifications

ModelFemale VCR Diaphragm Sealed Valve